- ZK
- Shenzhen
- 7days
- 100/days
1. MPPT efficiency more than 99%.
2. Drives well all 1/3 phase AC pumps and PMSM in solar pumping system.
3. VMP of solar panel can set by manual or MPPT automatically tracking.
4. Solar DC & Grid AC power input,
5. Short circuit, over load, over current... motor production.
6. Dry run & Full water tank protection.
7. The PQ (power/flow) performance curve enables calculating the flow output from the pump
8. Ambient temperature for using: -10 to +50˚C.
9. Inverter Power range:
220V: 0.75KW to 75KW.
380V/440/460/480V: 0.75KW to 250KW.
Model list:
No. | Model No. | Rate current (A) | Output voltage (VAC) | Rated power (KW) | MPPT voltage (VDC) |
Mini type 2S series : 150 to 450 VDC or 220/240VAC input, Vmp 310VDC, Voc 380VDC | |||||
1 | SG600-1K5GB-2S-M | 7A | 0-240VAC | 0.75KW | 260 to 375 |
2 | SG600-2K2GB-2S-M | 10A | 0-240VAC | 2.2kw | 260 to 375 |
Mini type 4T series : 250 to 800VDC or 380VAC input, Vmp 540VDC, Voc 650VDC | |||||
3 | SG600-1K5GB-4T-M | 3.7A | 380V-440V | 1.5KW | 486 to 750 |
4 | SG600-2K2GB-4T-M | 5A | 380V-440V | 2.2KW | 486 to 750 |
General type: 2S series 150 to 450 VDC or 220/240VAC input, Vmp 310VDC, Voc 380VDC | |||||
5 | SG600-0K7GB-2S | 4A | 220V/240V | 0.75KW | 260 to 375 |
6 | SG600-1K5GB-2S | 7A | 220V/240V | 1.5KW | 260 to 375 |
7 | SG600-2K2GB-2S | 10A | 220V/240V | 2.2KW | 260 to 375 |
8 | SG600-4K0GB-2S | 16A | 220V/240V | 4.0KW | 260 to 375 |
** | SG600-***GB-2S | ** | 220V/240V | Up to 75KW | 260 to 375 |
General type: 250 to 800/900 VDC or 380/480VAC input, Vmp 540VDC, Voc 650VDC | |||||
9 | SG600-0K7GB-4T | 2.5A | 380V-440V/480V | 0.75KW | 486 to 750 |
10 | SG600-1K5GB-4T | 3.7A | 380V-440V/480V | 1.5KW | 486 to 750 |
11 | SG600-2K2GB-4T | 5A | 380V-440V/480V | 2.2KW | 486 to 750 |
12 | SG600-4K0GB-4T | 10A | 380V-440V/480V | 4.0KW | 486 to 750 |
13 | SG600--5K5GB-4T | 13A | 380V-440V/480V | 5.5KW | 486 to 750 |
14 | SG600-7K5GB-4T | 17A | 380V-440V/480V | 7.5KW | 486 to 750 |
15 | SG600-011GB-4T | 22A | 380V-440V/480V | 11KW | 486 to 750 |
16 | SG600-015GB-4T | 30A | 380V-440V/480V | 15KW | 486 to 750 |
17 | SG600-018GB-4T | 37A | 380V-440V/480V | 18KW | 486 to 750 |
18 | SG600-022GB-4T | 45A | 380V-440V/480V | 22KW | 486 to 750 |
19 | SG600-030GB-4T | 60A | 380V-440V/480V | 30KW | 486 to 750 |
20 | SG600-037GB-4T | 75A | 380V-440V/480V | 37KW | 486 to 750 |
21 | SG600-045GB-4T | 91A | 380V-440V/480V | 45KW | 486 to 750 |
22 | SG600-055GB-4T | 110A | 380V-440V/480V | 55KW | 486 to 750 |
23 | SG600-075GB-4T | 150A | 380V-440V/480V | 75KW | 486 to 750 |
24 | SG600-090GB-4T | 180A | 380V-440V/480V | 90KW | 486 to 750 |
25 | SG600-110GB-4T | 220A | 380V-440V/480V | 110KW | 486 to 750 |
26 | SG600-**GB-4T | ** | 380V-440V/480V | Up to 250KW | 486 to 750 |
Technical Specifications:
Input voltage range | 80V to 450VDC input, 3PH 110VAC output, 1S model 150V to 450VDC input, 3PH 220VAC output, 2S/2T model 250V to 800/900VDC input, 3PH 380/440/480VAC output, 4T model |
Recommended input voltage (Voc and Vmp) | Voc 180VDC, Vmp 155VDC for 1S model & 110VAC pumps Voc 370VDC, Vmp 310VDC for 2T model & 220VAC pumps Voc 650VDC, Vmp 540VDC for 4T model & 380VAC pumps |
Motor type | Control for permanent magnet servo motor and asynchronous motor pumps. |
Input power | DC power from solar arrays or AC grid power |
Maximum DC power input | 450VDC for 220AC output & 800/900VDC for 380V AC output, (900V needs remark) |
Rated output voltage | Single phase 220V, 3-phase 220V/380V/480V |
Output frequency range | 0~50/60Hz |
MPPT efficiency | 99.6%, |
Ambient temperature range | G-type inverter with submersible pumps, and P type for general pumps. |
Solar pump control special performance | MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating. |
Protection function | Phase loss protection, phase short circuit protection , ground to phase circuit protection , input and output short circuit protection. Stall protection |
Protection degree | IP20, Air force cooling (IP54 is optional) |
Running mode | MPPT , CVT, variable frequency mode |
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m. |
Standard | CCC, CE, IEC |
Wiring diagram:
SG600 Solar pump inverter developed based on S100 high performance vector control frequency inverter
Hardware design:
Ti ‘s 32 bit DSP ( 28034/35), Germany Infineon intelligent modules;
Enhanded and 4 layer PCB design PCB wire corssing
Low temperature rising design with delta fans
Good quality components selecting,
Independent cooling duct for lower temperature rising.
SG600 Solar pump inverter software design with MPPT
Software ware design:
MPPT function: More than 99% efficiency
Solar DC and Grid AC can be input at same time used as hybrid inverter
Drives well all kind of pump, AM, PMSM, single phass
Auto detect the working DC voltage
Lowest stop frequency protection
Automatic sleep/wake up function
Flow and generated energy calculating and monitoring
Dry run, water tank detect, Over/under voltage, gound short circuit, phase loss, over current/load etc.
Built in RS485 interface, connect GPRS remote controller.
Now, ZK SG600 inverter is your best choice!