- ZK
- China
- 3-8 days
- 1000pcs per week
ZK SG600 series High MPPT solar pump inverter, strong MPPT efficiency and run stable, drives well all kind of pump in solar pumping system.
Drives well water pump in solar pumping system, including the Single phase pump.
Solar DC & Grid AC can be input at same time.
Solar water pump inverters have a wide range of applications, such as agricultural irrigation, desertification control, etc.
SG600 IEC Single Phase Solar Pump Inverter, Solar DC Input MPPT Solar Water Pump Inverter For irrigation
ZK SG600 Solar Pump Inverter Features
◆ Maximum power point tracking (MPPT) efficiency more than 99%.
◆ Solar DC and Grid AC input. 1/3Phase AC output.
◆ Drives well all kind of 1/3 phase AC pumps, AM and PMSM.
◆ Working voltage (Voc) can be set by manuel, also can auto tracking.
◆ Dry run, full tank detect protection.
◆ Motor maximum current protection.
◆ Low input power protection.
◆ Lowest stop frequency protection.
◆ Digital control for fully automatic operation, datastorage and protective functions.
◆ Intelligent power module (IPM) for the main circuit.
◆ LED & LCD is optional.
ZK SG600 Solar Pump Inverter Input Voltage Selection
Input voltage, power solar arrays selection | ||||
Pumps model | Inverte models | Vmp | Voc | Total Power of solar arrays |
110VAC pumps | 1S | 130VDC | 156VDC | ≧ (1.3 to 2.0) rated power of pumps It is also depend on the quality of solar panels. The more power input, the better performance. |
220VAC pumps | 2S | 310VDC | 372VDC | |
380VAC pumps | 4T (Max 800VDC) | 540VDC | 648VDC |
ZK SG600 Solar Pump Inverter Data Sheet
Recommended input Voltage | Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps Voc 380(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps Voc 650(VDC), Vmpp 520(VDC) for 4T model or 380V AC pumps |
Motor type | AM and PMSM |
Rated output voltage | Single phase or three, 110V/220V. 3 phase, 220V/380V/460V/480V |
Output frequency | 0~50/60HZ. |
MPPT efficiency | More than 99.5%, |
Ambient temperature range | G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s . P type for general pumps, 120% rated current for 60s, 150% rated current for 2s |
Solar pump control model | MPPT ( maximum power point tracking), CVT (constant voltage tracking), VF for AC input |
Protection function | Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection |
Protection degree | IP20, Air force cooling (IP54 & IP65 is avaliable) |
Running mode | MPPT or CVT |
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m. |
Ambient temperature for using | -10 to + 50℃ |
Technical specification of variable frequency inverter when PE00=0(solar pump disable) | |
voltage, frequency | 1 phase 220V, 3 phase, 220V,380V, 660V, 0-50/60Hz |
Control mode | 0: VF control ; 1: Open loop vector control mode 2: Close loop vector control mode |
Maximum frequency | 0-600Hz in vector control mode, or for PMSM. |
Multiple-functions | PID Control, VF control, Current Limiter, Speed Search, Momentary Power Loss Restart,16 Step Speed (Max), 3-Wire connection, Slip Compensation, Frequency Jump, DC braking, Upper/Lower Frequency, Torque control, Compatible for PMSM and IM, built in RS485. |
ZK SG600 Solar Pump System
ZK SG600 Solar Pump Inverter Wiring Steps
ZK SG600 Solar Pump Inverter Application
Solar Pump Inverter is widely used in agriculture and forestry irrigation, desert control, grassland animal husbandry, domestic water, urban waterscape, seawater (brackish water) desalination, etc. It uses solar energy, a clean and renewable energy, to provide a stable and reliable water source for these fields.
solar hybrid pomp hybrids solar inverter water frequency drive solar pump controller inverter manufacturing ac motor controller invert solar inverters solar pump invert solar invert system solar pumping inverter water pump invert solar water pump vfd solar solar invert vfd