The SG600 series solar pump inverters is a low voltage pumps inverter of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).
The inverters is customized to operate in dual supply mode (Ac and DC), so the grid connected supply is used in the absence of energy from PV cells. This drive functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.
SG600 Solar pumps inverter MPPT solar pump controller:
SG600 solar pump inverter features:
The SG600 series solar pump inverter is a low voltage AC drive of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).
The inverter is customized to operate in dual supply mode (AC and DC), so the grid connected supply is used in the absence of energy from PV cells. This inverters functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.
1. Maximum power point tracking (MPPT) with fast response speed and stable operation efficiency > 99.6%;
2. High speed running when sunlight radiation is good, frequency reduce fast when sunlight is become weak, stop running when output frequency lower lower limit frequency setting.
3. Suits for most 3 phase AC pumps and AC PMSM high efficiency pumps.
4. The working voltage of solar panel can set by manual or MPPT automatically tracking
5. Compatible with dual power input, AC grid and DC power supply input.
6. Built in automatic sleep-wake up function, start by timer is option.
7. Dry run (under load ) protection
8. Motor maximum current protection
9. Low input power protection
10. Lowest stop frequency protection
11. The PQ (power/flow) performance curve enables calculating the flow output from the pump
12. Digital control for fully automatic operation, data storage and protective functions
13. Intelligent power module (IPM) for the main circuit
14. LED display operating panel and support remote control
15. Low water probe sensor, and water level control function
16. Strong lightning protection
17. Easy operation and CVT auto detection function
18. GPRS function is option for remote start and stop, remote parameters setting.
Solar pump inverter models and specification:
N | Models | Rate current | Output voltage ( 3PH VAC) | Applicable for pumps | MPPT voltage (VDC) |
Mini type 2S series : 90/150 to 450 VDC or 220VAC input,Vmp 310V, Voc 380V | |||||
1 | SG600-0K7GB-2S-M | 3.8A | 0-220VAC | 0.75KW | 260 to 375 |
2 | SG600-1K5GB-2S-M | 7A | 0-220VAC | 1.5KW | 260 to 375 |
3 | SG600-2K2GB-2S-M | 10A | 0-220VAC | 2.2KW | 260 to 375 |
4 | SG600-4K0GB-2S | 17A | 0-220VAC | 4.0KW | 260 to 375 |
General type: 4T, 250/350 to 800 VDC or 380VAC input, Vmp520, Voc650 | |||||
1 | SG600-0K7GB-4T | 2.3A | 0-380V | 0.75KW | 486 to 750 |
2 | SG600-1K5GB-4T | 3.8A | 0-380V | 1.5KW | 486 to 750 |
3 | SG600-2K2GB-4T | 5.1A | 0-380V | 2.2KW | 486 to 750 |
4 | SG600-4K0GB-4T | 10A | 0-380V | 4.0KW | 486 to 750 |
5 | SG600-5K5GB-4T | 13A | 0-380V | 5.5KW | 486 to 750 |
6 | SG600-7K5GB-4T | 17A | 0-380V | 7.5KW | 486 to 750 |
7 | SG600-011GB-4T | 25A | 0-380V | 11KW | 486 to 750 |
8 | SG600-015GB-4T | 32A | 0-380V | 15KW | 486 to 750 |
9 | SG600-018GB-4T | 37A | 0-380V | 18KW | 486 to 750 |
10 | SG600-022GB-4T | 45A | 0-380V | 22KW | 486 to 750 |
11 | SG600-030G-4T | 60A | 0-380V | 30KW | 486 to 750 |
12 | SG600-037G-4T | 75A | 0-380V | 37KW | 486 to 750 |
13 | SG600-045G-4T | 91A | 0-380V | 45KW | 486 to 750 |
14 | SG600-055G-4T | 110A | 0-380V | 55KW | 486 to 750 |
15 | SG600-075G-4T | 150A | 0-380V | 75KW | 486 to 750 |
16 | SG600-090G-4T | 180A | 0-380V | 90KW | 486 to 750 |
17 | SG600-110G-4T | 220A | 0-380V | 110KW | 486 to 750 |
18 | SG600-132G-4T | 260A | 0-380V | 132KW | 486 to 750 |
19 | SG600-160G-4T | 320A | 0-380V | 160KW | 486 to 750 |
20 | SG600-185G-4T | 377A | 0-380V | 185KW | 486 to 750 |
21 | SG600-200G-4T | 426A | 0-380V | 200KW | 486 to 750 |
22 | SG600-220G-4T | 465A | 0-380V | 220KW | 486 to 750 |
23 | SG600-250G-4T | 465A | 0-380V | 250KW | 486 to 750 |
24 | SG600-280G-4T | 520A | 0-380V | 280KW | 486 to 750 |
25 | SG600-315G-4T | 585A | 0-380V | 315KW | 486 to 750 |
26 | SG600-355G-4T | 650A | 0-380V | 355KW | 486 to 750 |
27 | SG600-400G-4T | 725A | 0-380V | 400KW | 486 to 750 |
Solar pump inverter technical specification:
Solar pump inverter specification when PE-00=1&2 | |
Recommended MPPT voltage range | Vmp 131 to 350 VDC for 1s 3 phase 110VAC pumps Vmp 260 to 355VDC for 2S 3 phase 220VAc pumps Vmp 486 to 650 VDC for 4T 3 phase 380VAc pums |
Recommended input Voc and Vmpp voltage | Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps Voc 380(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps Voc 650(VDC), Vmpp 520(VDC) for 4T model or 380V AC pumps Voc 820(VDC), Vmpp 676(VDC) for 5T model or 480V AC pumps |
Motor type | Control for permanent magnet synchronous motor and asynchronous motor pumps. |
Rated output voltage | 1/3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V |
Output frequency range | 0~maximum frequency 600Hz. |
MPPT efficiency | Above 99.6%, |
Ambient temperature range | G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s . P type for general pumps, 120% rated current for 60s, 150% rated current for 2s |
Solar pump control special performance | MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected |
Protection function | Phase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection |
Protection degree | IP20, Air force cooling |
Running mode | MPPT or CVT |
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m. |
Enhanced version of AC drive | CE, Design based on vector control motor AC drive, more specification please refer to S600 or S600 vector control drive operation manual |
Solar pump inverter comissioning: