• 1hp Solar Water Pump Inverter
  • 1hp Solar Water Pump Inverter
  • 1hp Solar Water Pump Inverter
  • video
1hp Solar Water Pump Inverter
  • ZK
  • Guangdong,China
  • 3-7working days
  • 600pcs/day

Solar pumping system converts solar energy directly into electric energy, and then drives motors to drive water pumps to pump water from deep wells, rivers, lakes and other water sources. The system consists of solar panels, solar pump inverter and water pump.
The solar pump inverter operates in dual supply mode either with a three phase input supply from the grid or with DC input supply from PV cells.

1HP 220V 380V small power 0.75kw solar water pump inverter for ac pump


solar inverter for 2.2kw water pump

solar vfd pump driveinverter for 1hp submersible pump


Technical Specification:


Recommended MPPT voltage range

Vmpp 131 to 350 VDC for 1S (80V to 350VDC input, 3PH 110 to 220VAC output)
Vmpp 280 to 375VDC for 2T ( 150V to 350VDC input, 3PH 220 to 240VAC output)
Vmpp 486 to 800 VDC for 4T ( 250V to 900VDC input, 3PH 380 to 460VAC output)

Recommended input voltage (Voc and Vmmp)

Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps
Voc 355(VDC), Vmpp 310(VDC) for 2T model or 220V AC pumps
Voc 620(VDC), Vmpp 540(VDC) for 4T model or 380V AC pump

Motor type

Control for permanent magnet servo motor and asynchronous motor pumps.

Input power

DC power from solar arrays or AC grid power

Maximum DC power input

450VDC for 220-240VAC output /900VDC for 380-460VAC output

Rated output voltage

3-phase , 110V/160V/220V. 3-phase, 220V/240V/380V/460V/480V

Output frequency range

0~50/60Hz

MPPT efficiency

97%,

Ambient temperature range

(G-type inverter with submersible pumps, and P type for general pumps.

Solar pump control special performance

MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation,
dry run protection, low stop frequency protection, minimum power input, motor maximum
current protection, flow calculating, energy generated calculating

Protection function

Phase loss protection, phase short circuit protection , ground to phase circuit protection , input
and output short circuit protection. Stall protection

Protection degree

IP20, Air force cooling

Running mode

MPPT , CVT, variable frequency mode

Altitude

Below 1000m; above 1000m, derated 1% for every additional 100m.



ZK SG600  solar pump inverter voltage range:


Model

Applicable for
pumps

Input DC
voltage

Over voltage
point

Under voltage
point

Suggest
Vmp

Suggest
Voc

SG600-2T

For 200V AC

150V-450V

450V

100V

310VDC

380VDC

SG600-4T

For 400V AC

250V– 800V

800V

200V

520VDC

650VDC



Model number list and specificaions:


SG600-2S Series: input 150-450VDC, Three phase 220VAC output

SG600-0K75GB-2S-M

0.75KW

0.75KW

220

100-450

260-355

220-240

7A

0-600

SG600-1K5GB-2S-M

1.5KW

1.5KW

220

100-450

260-355

220-240

7A

0-600

SG600-2K2GB-2S-M

2.2kw

2.2kw

220

100-450

260-355

220-240

10A

0-600

SG600-4K0GB-2S

4.0KW

4.0KW

220

100-450

260-355

220-240

16A

0-600

SG600-4T Series: input 250-800VDC, Three phase 380VAC output

SG600-0K7GB-4T

0.75KW

0.75KW

380

250-800

450-650

380-440

2.5A

0-600

SG600-1K5GB-4T

1.5KW

1.5KW

380

250-800

450-650

380-440

3.7A

0-600

SG600-2K2GB-4T

2.2KW

2.2KW

380

250-800

450-650

380-440

5A

0-600

SG600-4K0GB-4T

4.0KW

4.0KW

380

250-800

450-650

380-440

10A

0-600

SG600-5K5GB-4T

5.5KW

5.5KW

380

250-800

450-650

380-440

13A

0-600

SG600-7K5GB-4T

7.5KW

7.5KW

380

250-800

450-650

380-440

17A

0-600

SG600-011GB-4T

11KW

11KW

380

250-800

450-650

380-440

25A

0-600

SG600-015GB-4T

15KW

15KW

380

250-800

450-650

380-440

32A

0-600

SG600-018GB-4T

18KW

18KW

380

250-800

450-650

380-440

37A

0-600

SG600-022GB-4T

22KW

22KW

380

250-800

450-650

380-440

45A

0-600

SG600-030GB-4T

30KW

30KW

380

250-800

450-650

380-440

60A

0-600

SG600-037GB-4T

37KW

37KW

380

250-800

450-650

380-440

75A

0-600

SG600-045GB-4T

45kw

45kw

380

250-800

450-650

380-440

90A

0-600

SG600-055GB-4T

55KW

55KW

380

250-800

450-650

380-440

110A

0-600

SG600-075GB-4T

75KW

75KW

380

250-800

450-650

380-440

150A

0-600




Solar pump inverter wiring steps:

solar inverter for 2.2kw water pump


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right