Solar pumping system converts solar energy directly into electric energy, and then drives motors to drive water pumps to pump water from deep wells, rivers, lakes and other water sources. The system consists of solar panels, solar pump inverter and water pump.
The solar pump inverter operates in dual supply mode either with a three phase input supply from the grid or with DC input supply from PV cells.
1HP 220V 380V small power 0.75kw solar water pump inverter for ac pump
Technical Specification:
Recommended MPPT voltage range | Vmpp 131 to 350 VDC for 1S (80V to 350VDC input, 3PH 110 to 220VAC output) | |||||||||
Recommended input voltage (Voc and Vmmp) | Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps | |||||||||
Motor type | Control for permanent magnet servo motor and asynchronous motor pumps. | |||||||||
Input power | DC power from solar arrays or AC grid power | |||||||||
Maximum DC power input | 450VDC for 220-240VAC output /900VDC for 380-460VAC output | |||||||||
Rated output voltage | 3-phase , 110V/160V/220V. 3-phase, 220V/240V/380V/460V/480V | |||||||||
Output frequency range | 0~50/60Hz | |||||||||
MPPT efficiency | 97%, | |||||||||
Ambient temperature range | (G-type inverter with submersible pumps, and P type for general pumps. | |||||||||
Solar pump control special performance | MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, | |||||||||
Protection function | Phase loss protection, phase short circuit protection , ground to phase circuit protection , input | |||||||||
Protection degree | IP20, Air force cooling | |||||||||
Running mode | MPPT , CVT, variable frequency mode | |||||||||
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m. |
Model | Applicable for | Input DC | Over voltage | Under voltage | Suggest | Suggest |
SG600-2T | For 200V AC | 150V-450V | 450V | 100V | 310VDC | 380VDC |
SG600-4T | For 400V AC | 250V– 800V | 800V | 200V | 520VDC | 650VDC |
Model number list and specificaions:
SG600-2S Series: input 150-450VDC, Three phase 220VAC output | ||||||||
SG600-0K75GB-2S-M | 0.75KW | 0.75KW | 220 | 100-450 | 260-355 | 220-240 | 7A | 0-600 |
SG600-1K5GB-2S-M | 1.5KW | 1.5KW | 220 | 100-450 | 260-355 | 220-240 | 7A | 0-600 |
SG600-2K2GB-2S-M | 2.2kw | 2.2kw | 220 | 100-450 | 260-355 | 220-240 | 10A | 0-600 |
SG600-4K0GB-2S | 4.0KW | 4.0KW | 220 | 100-450 | 260-355 | 220-240 | 16A | 0-600 |
SG600-4T Series: input 250-800VDC, Three phase 380VAC output | ||||||||
SG600-0K7GB-4T | 0.75KW | 0.75KW | 380 | 250-800 | 450-650 | 380-440 | 2.5A | 0-600 |
SG600-1K5GB-4T | 1.5KW | 1.5KW | 380 | 250-800 | 450-650 | 380-440 | 3.7A | 0-600 |
SG600-2K2GB-4T | 2.2KW | 2.2KW | 380 | 250-800 | 450-650 | 380-440 | 5A | 0-600 |
SG600-4K0GB-4T | 4.0KW | 4.0KW | 380 | 250-800 | 450-650 | 380-440 | 10A | 0-600 |
SG600-5K5GB-4T | 5.5KW | 5.5KW | 380 | 250-800 | 450-650 | 380-440 | 13A | 0-600 |
SG600-7K5GB-4T | 7.5KW | 7.5KW | 380 | 250-800 | 450-650 | 380-440 | 17A | 0-600 |
SG600-011GB-4T | 11KW | 11KW | 380 | 250-800 | 450-650 | 380-440 | 25A | 0-600 |
SG600-015GB-4T | 15KW | 15KW | 380 | 250-800 | 450-650 | 380-440 | 32A | 0-600 |
SG600-018GB-4T | 18KW | 18KW | 380 | 250-800 | 450-650 | 380-440 | 37A | 0-600 |
SG600-022GB-4T | 22KW | 22KW | 380 | 250-800 | 450-650 | 380-440 | 45A | 0-600 |
SG600-030GB-4T | 30KW | 30KW | 380 | 250-800 | 450-650 | 380-440 | 60A | 0-600 |
SG600-037GB-4T | 37KW | 37KW | 380 | 250-800 | 450-650 | 380-440 | 75A | 0-600 |
SG600-045GB-4T | 45kw | 45kw | 380 | 250-800 | 450-650 | 380-440 | 90A | 0-600 |
SG600-055GB-4T | 55KW | 55KW | 380 | 250-800 | 450-650 | 380-440 | 110A | 0-600 |
SG600-075GB-4T | 75KW | 75KW | 380 | 250-800 | 450-650 | 380-440 | 150A | 0-600 |
Solar pump inverter wiring steps: