Achieved high performance,high quality,small size installation area,design of high power density,high efficiency,energy saving,small startup current,high return Big start torque,low control accuracy is high ,the motor temperature rise ,its rich functions,application is simple , the advantages of stable performance more flexible the user`s experience.
Designed for controlling and adjusting the speed and torque of three phase ac motor.
3 phase variable frequency drive introduction:
S100 series ac drive covers a wide range of options. Ideal for variable and constant torque applications from pumps and fans to conveyors and mixers as well as many other variable and constant torque applications.
Features:
VF and Sensorless Vector Control
High reliability and high software performance motor drive with rich and perfect software&hardware functions to meet the application needs of most industrial sites;
can drive asynchronous motor and permanent magnet synchronous motor(PMSM) simultaneously. It could run with vector control without PG card, vector control with PG card, speed/torque control and position servo control.
Adopt advanced software vector control algorithm, which can provide high performance open loop vector control for asynchronous motor and synchronous motor. Meanwhile, simple vector control of asynchronous motor and synchronous motor can be used to meet the requirements of general speed adjustment application.
Built-in PID controller, the improved PID function can satisfy most of the on-site process control, such as the closed-loop control of temperature, pressure and flow.
Multiple protection function to ensure the safety of the drive and motor.
Standard 485 communication interface, support Modbus/RTU communication protocol, direct and upper computer communication for field bus control; Profibus-DP and CAN function also optional.
Technical Specifications:
Items | Specification | |||
Control mode | Control mode | V/F control | Sensorless in open loop | Close loop vector control |
Starting torque | 0.5Hz 150% | 0.5Hz 180% | 0.00Hz 180% | |
Speed adjust range | 0:50 | 0.111111111 | 0.736111111 | |
Speed stabilizing | ±1% | ±0.1% | ±0.02% | |
precision | ||||
Torque precision | NO | NO | ±5% | |
Motor type | General induction motor | |||
permanent magnet synchronous motor (PMSM ) | ||||
Function design | Highest frequency | General vector control :320Hz | ||
V/f control: 3200Hz | ||||
frequency resolution | Digital setting: 0.01Hz | |||
Analog setting:maximum×0.025% | ||||
Carrier frequency | 0.5K~16KHz, the carrier frequency can be adjusted by temperature automatically | |||
Frequency reference setting method | Digital of Control panel, analog AI1, AI2, potentiometer of control panel, UP/DN control, communication, PLC pulse frequency | |||
Acceleration./deceleration characteristic | Linear curve and S curve accel. /decel. mode, range of time: 0.0 to 65000S. | |||
V/F curve | 3 mode: linear, multiple points, N Power | |||
V/F separation | 2 times separation: totally separation, half separation | |||
DC braking | DC braking frequency: 0.0 to 300Hz, | |||
DC braking current: 0.0% to 100% | ||||
Braking unit | Standard built in for up to 4T22G (22kw), optional built it for 4T30G~4T110G (30kw to 110kw), external built for above 4T160kw . | |||
Jog function | Job frequency range: 0.0 to 50.0Hz, the acceleration and deceleration time of Jog | |||
Configured PID function | Easy to perform pressure, flow, temperature close loop control. | |||
PLC multiple speed | To achieve 16 segment speed running through built in PLC or terminal control | |||
Common Dc bus | Multiple drives use one DC bus for energy balance. | |||
Auto voltage regulation (AVR) | Enable to keep output voltage constant when grid fluctuation | |||
Over load tolerance capability | G type model: 150% rated current for 60s, 180% rated current for 3s, | |||
P type Model: 120% rated current for 60s, 150% rated current for 3s. | ||||
Stall protection control when over current, over voltage | Carry out limiting automation for running current, voltage to prevent over current, over voltage frequently | |||
Rapid current limit function | Minimize the IGBT module broken to protect the AC Drive, maximum reduce the over current fault. | |||
Torque limit and torque control | "Excavator" characteristics , torque limit automatically during motor running. Torque control is available in close loop vector control mode. | |||
Features | Friendly interface | Display “Hello” when power on. | ||
Multiple function key JOG button | It can set for Forward Jog, reverse Jog, forward/reverse switch | |||
Timing control function | A total running time and total running time calculating | |||
2 group motor parameters | To achieve two motor switchover freely, control mode is selectable | |||
Motor over heat protection | Accepting motor temperature sensor signal input via AI1 terminals. | |||
Multiple kinds encoder * | Compatible collector PG, differential PG, and rotary transformer Encoder( resolver). | |||
Command source | Control panel, control terminals, series communication, switch freely. | |||
Frequency source | Digital setting, analog current/voltage, pulse setting, serial communication, main and auxiliary combination. | |||
Protection function | Short circuit detect when power on, input/output phase loss, over voltage, over current, under voltage, over heat, over load protection. | |||
Environment | Application site | Indoor, free of exposure to sunlight, no dusty, no corrosive, no inflammable gas, no oil and water vapor, and water dipping | ||
Altitude | Lower 1000m | |||
Environment temperature | -10℃~+40℃, power derated for 40~50℃, rated current derated 1% for 1℃ increasing. | |||
humidity | Less than 95%, no water condense. | |||
storage | -40~+70℃ | |||
IP degree | IP20 |
Model List:
Model | Power Supply Capacity(KVA) | Input Current (A) | Output Current (A) | Applicant Motor | Dimensions (mm) | Weight (kg) | |
Single-phase power: 220v, 50/60Hz | KW | HP | |||||
S100-2S0.7GB | 1 | 5.4 | 2.3 | 0.4 | 0.5 | 130*85*125 | 1.6 |
S100-2S1.5GB | 1.5 | 8.2 | 4 | 0.75 | 1 | 1.6 | |
S100-2S2.2GB | 3 | 14 | 7 | 1.5 | 2 | 1.6 | |
S100-2S4.0GB | 4 | 23 | 9.6 | 2.2 | 3 | 247*160*175 | 2.5 |
Three-phase power: 380v, 50/60Hz | |||||||
S100-4T-0.7GB | 0.75/1.5 | 3.4 | 3/4 | 0.75 | 1 | 185*118*155 | 2.2 |
S100-4T-1.5GB | 1.5/2.2 | 5 | 4/6 | 1.5 | 2 | 2.25 | |
S100-4T-2.2GB | 2.2/4 | 5.8 | 6/9.2 | 2.2 | 3 | 2.3 | |
S100-4T-4.0GB/5.5PB | 4/ 5.5 | 11 | 9.2/13 | 3.7 | 5 | 2.35 | |
S100-4T-5.5GB/7.5PB | 5.5 / 7.5 | 14.6 | 13/17 | 5.5 | 7.5 | 247*160*175 | 3.95 |
S100-4T-7.5GB/11PB | 7.5/ 11 | 20.5 | 17/25 | 7.5 | 10 | 4 | |
S100-4T-11GB/15PB | 11/15 | 26 | 25/32 | 11 | 15 | 4.1 | |
S100-4T15GB/18.5PB | 15 / 18 | 35 | 32/37 | 15 | 20 | 415*230*205 | 7 |
S100-4T-18.5G/22P | 18 / 22 | 38.5 | 37/45 | 18.5 | 25 | 7.1 | |
S100-4T-22G/30P | 22 / 30 | 46.5 | 45/60 | 22 | 30 | 11.4 | |
S100-4T-30G/37P | 30 / 37 | 62 | 60/75 | 30 | 40 | 480*260*215 | 16.5 |
S100-4T-37G/45P | 37 / 45 | 76 | 75/90 | 37 | 50 | 17 | |
S100-4T-45G/55P | 45 / 55 | 92 | 90/112 | 45 | 60 | 575*320*310 | 34.5 |
S100-4T-55G/75P | 55 / 75 | 113 | 112/150 | 55 | 75 | 36 | |
S100-4T-75G/90P | 75 / 93 | 157 | 150/176 | 75 | 100 | 620*380*310 | 46 |
S100-4T-90G/110P | 93 / 110 | 180 | 176/210 | 90 | 120 | 48 | |
S100-4T110G/132P | 110 / 132 | 214 | 210/253 | 110 | 150 | 49.5 | |
S100-4T132G/160P | 132 / 160 | 256.0 | 253/304 | 132 | 175 | 500*780*340 | 50 |
Applications: Air Compressor, Oil, Warming and Water Supply, Plastics Machine, Mine, Fans and Water Pumps.